Vacuum gauge VAM, EN 837-1. Temperature range –10 … +60 °C. Pressure –1 … +9 bar. Analogue display via Bourdon tube. Vacuum gauges can be loaded up to ¾ of their full scale value under static load and up to 2/3 under intermittent load conditions. Vacuum gauge VAM, EN 837-1, with red-green range. Temperature range –10 … +60 °C. Pressure –1 … 0 bar. Analogue display via Bourdon tube. Vacuum gauges can be loaded up to ¾ of their full scale value under static load and up to 2/3 under intermittent load conditions. The adjustable red-green range provides additional safety when monitoring compressed air.
Temperature range 0 … +40 °C. Operating pressure –0.95 … 0 bar The vacuum filter is used to filter particles in the direction of suction. The vacuum filter is inserted as an inline filter in the tubing line. On initial installation any flow direction can be chosen. After disassembly and installation of the vacuum filter the original flow direction must be kept. The fabric filter element is located in a transparent housing so that the degree of contamination of the filter cartridge can be identified. It is not possible to replace the filter.
The ISV valve is fitted between the vacuum generator and the suction cup. If, during vacuum generation, a suction cup is uncovered, or only partly covered, the ISV automatically stops the influx of air. When the suction cup fits tightly against the surface, a vacuum is regenerated. Removal of the object from the suction cup causes the ISV valve to close immediately. Temperature range –10 … +60 °C. Operating pressure –0.95 … 0 bar.
Nominal width 0.45 … 3 mm. Max. vacuum 85%. Temperature range 0 … +60 °C. Compact design. Minimal installation work required. Short switching times. Integrated solenoid valve (on/off). VADMI: additional integrated solenoid valve for ejector pulse. Filter with display. Optional air saving function. Vacuum switch (optional). Reliable setting down of workpieces.
Nominal size 0.45 … 3 mm. Max. vacuum 93%. Temperature range 0 … +60 °C. A range of extremely effective generators suitable for use directly in the workplace. Available as straight or T-shaped housing. Low space requirement. Low-cost. No wearing parts. Extremely fast evacuation time. Vacuum switch (optional) Optional with additional functions: – integrated eject pulse – electric control for vacuum ON/OFF – combination of eject pulse and control
For suction cups with connection attachments/suction cups, bellows with 3.5 convolutions. The suction cup insert is compatible with the ESG suction gripper range. It is suitable for bellows suction cups with 3.5 convolutions and is simply snapped into the bellows. The support offered by the suction cup insert enables delicate and fragile workpieces to be transported. Areas of application: – Semiconductor industry (wafers, solar cells) – Electronics industry (printed circuit boards, plastic film) – Paper industry – PE film
Mounting plate VN-T for vacuum generators VN-A/B/M. Internet: vn. For wall mounting with through hole for housing type T3/T4. Material: Plate: Galvanised steel. RoHS-compliant. Free of copper and PTFE. Mounting bracket VAF-DB-HR for vacuum filter VAF-DB. Type of mounting: threaded. Max. tightening torque: 0.63 Nm. Materials: High-alloy stainless steel. Note on materials: RoHS-compliant. Contains PWIS (paint-wetting impairment substances)
Function NC, normally closed: Ejector pulse. QS fitting or G female thread. With open silencer. Prepared for common supply manifold NO, normally open: Ejector pulse. QS fitting or G female thread. With open silencer. Prepared for common supply manifold Temperature range 0 … +50 °C. Operating pressure 2 … 8 bar